Fifty Point Four, and Random Is Fifty

On 20 November OpenAI published MedChemBench, 99 medicinal chemistry problems built from 117 papers and patents, with a preprint dated 9 November. Each task drops a model into a real drug program at a decision point: here is the target, here are the compounds made so far, here are the assay tables and the binding poses, now tell us which molecule to advance. Results published later in the source paper are withheld and used as the answer key.

The headline is 83.83% for GPT-6 Astra at max reasoning effort, 83.33% at xhigh, the highest setting all eleven models share. The paper is candid that this is close to the ceiling: “The benchmark is also close to saturation in its current form.”

I read the rubric before the leaderboard, and the number I kept coming back to is 50.42.

Where the credit lives

Every task is normalized to a maximum score of 1, and the paper publishes how that point is divided. Averaged across all 99 tasks, molecular structure is 37.49% of the available score, scientific rationale 35.78%, ranking and candidate selection 17.51%, numerical and categorical prediction 8.92%, with 0.30% for technical checks.

Molecular structure credit is for reading the chemical drawings supplied in the prompt and returning isomeric SMILES strings that match the reference graph. Scientific rationale credit is for an explanation that a GPT-6 Astra judge at medium reasoning effort scores zero, half, or full against task-specific anchors.

So 73.27% of the available credit is transcription and judged prose. The decisions — which compound to advance, and what the next experiment will measure — carry 26.43% between them.

MedChemBench: where the credit is, and where the best model earns it Four grading components with two measures each. Share of available credit, averaged over all 99 tasks: molecular structure 37.49 percent, scientific rationale 35.78 percent, ranking and candidate selection 17.51 percent, numerical and categorical prediction 8.92 percent. Credit earned by GPT-6 Astra at xhigh effort within each component: molecular structure 95.37 percent, scientific rationale 91.05 percent, ranking and selection 50.42 percent, numerical prediction 47.02 percent. A dashed reference line marks 50 percent, the credit the paper says a uniformly random ordering earns. Source: MedChemBench preprint, 9 November 2026. RUBRIC COMPOSITION VS GPT-6 ASTRA ATTAINMENT · XHIGH · MEDCHEMBENCH PREPRINT SHARE OF CREDIT (0–40%) CREDIT EARNED (0–100%) Molecular structure Scientific rationale Ranking & selection Numerical prediction 37.49% of available credit — MedChemBench preprint, 9 Nov 2026 35.78% of available credit — MedChemBench preprint, 9 Nov 2026 17.51% of available credit — MedChemBench preprint, 9 Nov 2026 8.92% of available credit — MedChemBench preprint, 9 Nov 2026 37.5 35.8 17.5 8.9 50 95.37% of structure credit — GPT-6 Astra at xhigh 91.05% of rationale credit — GPT-6 Astra at xhigh 50.42% of ranking and selection credit — GPT-6 Astra at xhigh 47.02% of numerical prediction credit — GPT-6 Astra at xhigh 95.4 91.1 50.4 47.0 Left panel is the mean share of each task's point budget. Right panel is credit earned within the tasks where that component applies. Numerical prediction applies to 21 of the 99 tasks; structure to 92, rationale to 91, ranking and selection to 86.
The two biggest slices of the point budget are also the two the best model nearly maxes out. The decisions sit at the dashed line.

Fifty point four against what

The grading rules score ranking criteria pairwise: “Correctly ordered pairs within the full ordering receive credit of 1, reversed pairs receive 0, and predicted ties receive 0.5.” Then: “In this approach, a uniformly random ordering has expected credit of 0.5.”

GPT-6 Astra earns 50.42% of the ranking-and-selection credit at xhigh. Across all eleven models the component spans 43.58% to 52.78%.

I want to be careful about what that does and doesn’t show, because the component mixes two scoring rules. Pairwise ranking is the one with the 0.5 chance baseline. Set-selection criteria are scored by Jaccard similarity between the predicted and reference sets, where guessing does much worse than half. So 50.42% is not a clean “no better than chance” result — a model could be beating chance on the sets and losing on the orderings, and land there.

But that is the point. The paper doesn’t publish the split. It reports a component in which the strongest model, the weakest model, and a coin are all within about nine points of each other, and it does so without separating the sub-score whose null value it has already told us is 50.

Compare that with the spread on the components the models do separate on.

Model spread by grading component at xhigh effort For each of four grading components, the range of credit earned across eleven GPT models at xhigh effort, with GPT-6 Astra marked by a filled dot. Molecular structure runs from 8.74 to 95.37 percent, an 87-point spread, Astra at the top. Scientific rationale runs from 50.94 to 91.05, a 40-point spread, Astra at the top. Ranking and candidate selection runs from 43.58 to 52.78, a 9-point spread, with Astra at 50.42, inside the range. Numerical prediction runs from 37.69 to 47.02, a 9-point spread, Astra at the top. A dashed vertical line at 50 marks the credit a uniformly random ordering earns under the pairwise ranking rule. Source: MedChemBench preprint, 9 November 2026. RANGE ACROSS ELEVEN MODELS · FILLED DOT = GPT-6 ASTRA · ORDERED BY SPREAD random ordering = 50 Molecular structure Scientific rationale Ranking & selection Numerical prediction GPT-6 Astra 95.37% — structure, xhigh GPT-6 Astra 91.05% — rationale, xhigh GPT-6 Astra 50.42% — ranking and selection, xhigh GPT-6 Astra 47.02% — numerical prediction, xhigh 8.7 50.9 43.6 37.7 95.4 91.1 52.8 47.0 Astra 50.4 0 25 75 100 Astra holds the top of three ranges; on ranking and selection it sits inside the range, below the 52.78 earned by another model. The 50 line is the null for the pairwise-ranking criteria only; set-selection criteria in the same component score by Jaccard overlap.
Eighty-seven points of spread on redrawing the molecule. Nine points on choosing which one to make.

Molecular structure separates models by 87 points. Scientific rationale by 40. The two components that require predicting something the model was not shown separate them by about nine each. Whatever the benchmark is measuring when it ranks GPT-6 Astra above GPT-5.6 Sol, it is mostly measuring the ability to turn a picture of a molecule into a correct SMILES string.

Half credit at twofold, in assays that move threefold

The numerical component has a second problem, and it isn’t the model’s.

Most numerical predictions are scored by fold error: credit is min(p, t) / max(p, t), so “an exact prediction earns full credit, while a prediction that is twice or half the reference value earns half credit.” The reference t is one number from one published experiment.

Potency measurements are not that stable. The standard statistic for this is the minimum significant ratio, which Brian Eastwood and seven colleagues defined in 2006 as the fold change between two compounds in the same run that can be treated as real rather than noise. They define it as 10 raised to Z(α/2)·√2·σ, and they report their internal threshold plainly: “in our company, we have set general acceptance criterion for assays of an MSR ≤3.” An assay whose same-run MSR is 3 is a passing assay. Two compounds in it can differ threefold in measured IC50 and the difference still isn’t significant. They also note that across-run comparisons — which is what comparing a prediction to a published value is — “are usually more variable than comparisons within the same run.”

The ADME endpoints behave the same way. Mark Wenlock and Lars Carlsson pooled more than 463,000 AstraZeneca measurements across eight DMPK assays in 2014 and estimated the typical standard deviation of a repeat measurement: 0.12 log units for human microsomal intrinsic clearance, up to 0.28 for solubility from solid. At 0.12, the 99% interval on a single measurement reaches a factor of 2.0 either side of the true value. For solubility it is a factor of 5.3. MedChemBench asks models to predict human microsomal clearance and permeability, and scores them against single reported values.

Grading credit against fold error, with two noise reference points A decay curve of MedChemBench numerical credit, equal to one divided by fold error, plotted from a fold error of 1 to 5. Credit is 1.0 at exact agreement, 0.50 at twofold error, 0.33 at threefold, 0.20 at fivefold. A dashed horizontal line at 0.47, the mean numerical credit GPT-6 Astra earns at xhigh, meets the curve at a fold error of about 2.1. Two dashed vertical lines mark reference values from the measurement literature: 2.0, the factor either side of a single human microsomal clearance measurement in its own 99 percent interval, from a typical standard deviation of 0.12 log units; and 3.0, the minimum significant ratio one pharmaceutical company accepts as a passing assay, below which a potency difference between two compounds is not significant. Sources: MedChemBench preprint 2026; Eastwood et al. 2006; Wenlock and Carlsson 2014. CREDIT = 1 ÷ FOLD ERROR · AGAINST THE REPRODUCIBILITY OF THE REFERENCE 1.00 0.75 0.50 0.25 0 1× 2× 3× 4× 5× Exact agreement: full credit — MedChemBench grading rules Twofold error: half credit — MedChemBench grading rules Threefold error: credit 0.33 — MedChemBench grading rules Astra's mean numerical credit 0.47 meets the curve at 2.1-fold Astra mean credit 0.47 2.0× — one clearance measurement's own 99% interval, either side 3.0× — a passing assay's MSR: not a real difference between two compounds Curve is the benchmark's own rule for most numerical criteria. The 0.47 line is a mean over 21 tasks, so the typical miss is at least 2.1-fold. Clearance interval: 2.58 × 0.12 log units (Wenlock and Carlsson 2014). MSR criterion: Eastwood et al. 2006, one company's threshold.
Where the grading curve gets steep is where the measurements stop being able to tell the difference.

Astra’s mean numerical credit at xhigh is 47.02%. Because credit is the reciprocal of fold error, a mean of 0.47 is what you get if every prediction misses by about 2.1-fold; averaging over a skewed distribution, the typical miss is at least that. Two-point-one-fold on clearance is inside the window that one measurement of clearance can’t resolve to 99% confidence.

That cuts both ways. It doesn’t mean the model is better than it looks; it means this component can’t tell. The paper says as much in its future work, asking for “explicit treatment of reference assay uncertainty (as most reference answers are given as point estimates).” I would put that higher than future work. Eight-point-nine-two percent of the score is currently being awarded on a scale finer than the instrument.

Scott Brown, Steven Muchmore and Philip Hajduk simulated lead-optimization campaigns in 2009 and found that “prediction errors greater than 2.0 provide essentially no statistical enrichment for a typical LO campaign. Only when prediction errors fall below 1.0 are significant benefits expected.” Those are log units, so the bar is loose in that framing: a 2.1-fold error is 0.32 log. The sentence MedChemBench inherits is the simpler one. “The error in predictions of ligand affinities is unlikely to be less than the resolution (e.g. error) of the experimental data.” A benchmark that scores to the fold cannot separate a model at the resolution limit from one below it.

The judged prose and the wrong answer

On the MAP4K1 lead-selection task, the paper prints Astra’s rationale excerpts beside weaker models’ and awards Astra full credit on both reasoning criteria shown — it correctly places a spirocyclopropane at oxazine C6, and separates a binding hypothesis from an exposure effect instead of equating an ether oxygen with better pharmacokinetics. Then, in the same paragraph: “These differences concern the selected reasoning criteria, not the correctness of the final candidate sets; Astra also selected an incorrect qualifying set in this response.”

Full marks on the explanation, wrong compound. On this task the structures are 8 of 25 points, the rationale criteria 16, and picking the right qualifying compound is 1. That is a defensible way to grade an essay about a drug program. It is not a way to grade the decision.

What would make the number mean what it says

Three changes, all of which the paper has the data for:

  1. Split the ranking-and-selection score into pairwise-ranking credit and Jaccard set credit, and print the chance baseline next to the first one. A component whose null is 50 should never be reported without it.
  2. Grade the numerical criteria against the reference’s own uncertainty, not a point estimate — full credit inside the assay’s minimum significant ratio, partial outside it. Where the source gives only one value, say so and widen the band.
  3. Report a decision-only score: the credit earned on ranking, selection and numerical prediction alone, with its own interval. For Astra at xhigh that is a different headline than 83.33%, and it is the one a chemist would want.

None of this makes MedChemBench a bad benchmark. The retrospective design is better than the synthetic alternative, the rubrics are published, the grading rules are explicit enough that I could check the chance baseline at all, and the contamination test — rerunning all 99 problems with the source DOI in the prompt, which moved scores by −0.23 to +0.80 points — is more than most launches attempt. The problem is that the number on the front is dominated by the part of the task that was already in the prompt as a picture.

I read a related demo in early November, where an agent retraced a known rigidification and the headline relationship turned out to be two PubChem fields. The shape repeats here. The part that looks like chemistry judgment keeps getting scored by whether the model reproduced something it was handed.

References

  1. OpenAI. “Can AI help scientists identify promising drug candidates?” 20 November 2026. openai.com/index/introducing-medchembench
  2. Li J, Ho A, Shringarpure S, Liu A, Humphries P, Jiao J. “MedChemBench: Evaluating complex multimodal reasoning in medicinal chemistry.” OpenAI, 9 November 2026. cdn.openai.com/pdf/…/medchembench-paper.pdf
  3. Eastwood BJ, Farmen MW, Iversen PW, Craft TJ, Smallwood JK, Garbison KE, Delapp NW, Smith GF. “The Minimum Significant Ratio: A Statistical Parameter to Characterize the Reproducibility of Potency Estimates from Concentration-Response Assays and Estimation by Replicate-Experiment Studies.” Journal of Biomolecular Screening (SLAS Discovery) 11(3):253–261, April 2006. doi:10.1177/1087057105285611
  4. Wenlock MC, Carlsson LA. “How Experimental Errors Influence Drug Metabolism and Pharmacokinetic QSAR/QSPR Models.” Journal of Chemical Information and Modeling 55(1):125–134, 24 December 2014. doi:10.1021/ci500535s
  5. Brown SP, Muchmore SW, Hajduk PJ. “Healthy skepticism: assessing realistic model performance.” Drug Discovery Today 14(7–8):420–427, April 2009. doi:10.1016/j.drudis.2009.01.012